150A Max Continuous Discharge (300A 30s Discharge)
150A Max Continuous Charge (300A 10s Charge)
IP67 Rated, Dust and WATERPROOF
HEATED - Internal heating for below 0C charging
BLUETOOTH - iOS and Android Apps
CANBUS Communication allows BMS to communicate directly with Victron OS
Mountable ON/OFF Switch
Mountable Battery gauge
Built-in Smart Battery Management System (BMS)
Internal fuse with current and temperature protections
Over charge and over discharge protection
Over current and short circuit protection
High & low temperature disconnects
3500+ Cycle life & Maintenance-free
11 Year Manufacturer Warranty
To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.