To properly charge your Epoch Batteries, you will want to verify that any charging component in your system is capable of being programmed for the following specifications. Charging components can include, but are not limited to converters, inverter chargers, solar charge controllers, DC to DC chargers, etc.
Bulk/Absorption: 14.2V – 14.6V
Absorption Time: Two batteries in parallel connections require 30 minutes 200Ah
Float: 13.4V – 13.8V
Equalization: 14.4V/ Disabled
Temperature Compensation: 0/Disabled
Charge Rate: 50% of the battery or battery bank capacity
Battery Charge Temperature Range: 32°F (0°C) to 131°F (55°C)
Battery Discharge Temperature Range: -4°F (-20°C) to 140°F (60°C)
Cell Charge Temperature: 32°F (0°C) to 131°F (55°C)
NOTE: Not all chargers are capable of multistage charging. If yours is not, you will want to verify it can be programmed for the Bulk/Absorption voltage and have the other items mentioned disabled if applicable. Consult your charger's manual or the manufacturer.
IP20
Experience worry-free adventures with our robust IP54 protection. Your battery is effectively shielded against dust and water splashes, giving you the confidence to use it in light rain or dusty conditions. While not fully waterproof, IP54 provides reliable protection for most everyday outdoor scenarios.